Technical Data
- Uf- value2
- ≥ 1,4 W/(m2K)
- System depth
- 75 mm
- Applications
- Facade Insert
- Max. weight turn-tilt surface-mounted fitting
- -
- Max. weight turn surface-mounted fitting
- 180 kg (with projected top-hung stay)
- Max. weight consealed fitting
- -
- Max. sash dimensions4
- 2.500 x 2.000 mm / 2.000 x 2.500 mm
- Infill thickness sash
- 22 - 68 mm
- Infill thickness fixed glazing
- -
2 Thermal insulation based on DIN ISO 10077-2
3 Applications outside these limits, would be subject to an assessment by our Technical Department
4 For authorized sash sizes, see fitting diagram in the relevant planning documents
* 130 / 160 kg with standard fitting up to 200 / 300 kg with reinforced fitting
Certification / Approval
- Air permeability1
- Class 4
- Resistance to wind load1
- up to class C4
- Resistance against impact1
- -
- Water tightness1
- up to E 900
- Operating forces1
- Class 1
- Airborne sound insulation2
- -
- Mechanical strength1
- -
- Burglar resistance
- -
- Continuous-operational testing EN 12400
- Class 2