THERM+ A-I – Aluminium façade
Contact expert advisorHighlights
Continuous thermal insulation
Seamless thermal insulation using RAICO insulation block technology
Perfect appearance
in the case of flush-fitting bolts with sharp-edged cross-sections
Integrated drainage
in the continuous hat-type seal on three levels
Water tightness
RE 1.650
Technical Data
- System width
- 50 / 56 mm
- Rectangular profile depth
- 25 – 200 mm
- Expansion profile depth
- 75 – 200 mm
- T-profile depth
- 50 – 200 mm
- T-profile width
- 50 mm
- Infill thickness
- 6 – 64 mm
- Glass weight
- bis 600 kg
- Drainage levels
- 2 oder 3
- Polygonal assembly
- bis 45°
- Application Glass roofs
- bis 2° Neigung
- Application Conservatories
- Ja
Certification / Approval
- Thermal insulation incl. screw influence
- down to Um,t = 0,85 W/(m2K)
- Wind resistance
- 1,875 / 2,813 kN/m2
- Resistance against impact
- Interior I5, Exterior E5
- Air permeability
- AE (>600)
- Water tightness
- RE 1.650
- Airborne sound insulation
- Rw (C; Ctr) = 35 (-1; -3) dB Rw (C; Csub>tr) = 40 (-1; -4) dB Rw(C; Csub>tr) = 44 (-2; -5) dB
- Fall protection (TRAV)
- yes, without additional measures
- German general approval
- curtain wall system Z-14.4-454, T-connector Z-14.4-461
- European Technical Approval
- -
- Fire resistance
- EI30
- Burglar resistance
- RC2 / RC3
Tests / Approvals / CE system certificates in accordance with EN 13830, the product standard for curtain walls
Variants

Structural Glazing
The THERM+ Structural Glazing SG2 curtain wall systems feature the most intricate glazing technique. A narrow silicone joint is the only visible line between the insulation glass panes. Retention of the internal pane is enabled easily, quickly and securely with the use of SG glazing toggles. By utilising the SG insulating block, curtain walls achieve outstanding thermal insulation values.

Burglar resistance
All THERM+ curtain wall variants may be made burglar resistant in accordance with the German resistance categories RC2 and RC3 by adding a few supplementary system components. Providing maximum creative possibilities, all system widths and all types of pressure plates with clip on cover caps, visible screw fixings, as well as flat pressure profile plates (in RC2) may be used.